curve-down

Description

Product recirculation from pump discharge through a Y strainer, a flow control orifice and a heat exchanger to seal chamber.

Features

  1. Improves pressure margin over vapour pressure.
  2. Improves temperature margin to meet secondary sealing element limits, to reduce coking or polymerizing and to improve lubricity.
  3. Self venting plan.
  4. Provides sufficient pressure difference to allow proper flow rate.

Use

  1.  For high temperature applications with slightly dirty liquid.

Caution

  1. Always ensure that the orifice is placed after the Y strainer.
  2. Always ensure that cooler is placed after the orifice. 
  3. Check pressure difference between discharge and seal chamber.
  4. Cooler duty is leading to fouling on waterside.
  5. This plan is normally discouraged due to non-reliability of Y strainer.
 
  • Read Our Water Savings Industry Guide

    This paper explains the problems associated with packing, how double mechanical seals with seal support systems solve these problems.

    Find Out More
  • API Piping Plan Booklet

    API Plans are standardized flushing piping arrangements that are widely used in industry. This downloadable pdf booklet describes both configurational parameters and application criteria

    Find Out More

Want an expert piping plan explanation?

Our API expert Richard Smith walks through some of the 4th Edition API Plans, providing expert analysis and explanation of each plan.

API video series thumbnail

Click to Watch

Did you know that you could see a return on investment whilst helping to save the environment?

Careful selection of configuration & product types can save your organisation and nature's valuable resources.

Take a Journey to 'Net Zero'